Capstone MicroTurbines are suitable for applications ranging from remote locations to city centers, delivering clean, high quality power from a wide variety of fuels, with superior safety and emissions.

Model
Fuels
Power Output (1)
Electrical Efficiency
Exhaust Gas Flow
Exhaust Temperature
Net Heat Rate
Dimensions (2)(W x D x H)
kW % kg/s lbm/s MJ/kWh btu/kWh m in
GASEOUS FUELS (3)
C30 LP NG 28 25 0.31 0.68 275 530 13.8 13,100 0.76 x 1.5 x 1.8 30 x 60 x 70
C30 HP NG, P, LG, DG 30 26 0.31 0.68 275 530 13.8 13,100 0.76 x 1.5 x 1.8 30 x 60 x 70
C30 HZLC (4) NG 30 26 0.32 0.70 275 530 13.8 13,100 0.87 x 2.9 x 2.2 34 x 112 x 85
C65 NG, P 65 29 0.49 1.08 309 588 12.4 11,800 0.76 x 1.9 x 1.8 30 x 77 x 76
C65 ICHP NG, P, LG, DG 65 29 0.49 1.08 309 588 12.9 12,200 0.76 x 2.2 x 2.4 30 x 87 x 93
C65 CARB NG 65 28 0.51 1.13 311 592 12.4 12,200 0.76 x 2.2 x 2.6 30 x 87 x 103
C65 CARB LG, DG 65 29 0.49 1.08 309 588 12.4 11,800 0.76 x 2.2 x 2.6 30 x 77 x 85
C65 HZLC (4) NG 65 29 0.50 1.09 325 617 12.9 12,200 0.87 x 3.2 x 2.3 35 x 128 x 90
C200 LP NG 190 31 1.3 1.09 280 535 11.6 11,000 1.7 x 3.8 x 2.5 67 x 150 x 98
C200 HP NG, P, LG, DG 200 33 1.3 2.9 280 535 10.9 10,300 1.7 x 3.8 x 2.5 67 x 150 x 98
C200 HZLC (4) NG 200 33 1.3 2.9 280 535 10.9 10,300 1.9 x 3.2 x 3.1 74 x 126 x 122
C600 LP NG 570 31 1.3 8.8 280 535 11.6 11,000 2.4 x 9.1 x 2.9 96 x 360 x 114
C600 HP NG, P, LG, DG 600 33 4.0 8.8 280 535 10.9 10,300 2.4 x 9.1 x 2.9 96 x 360 x 114
C800 LP NG 760 31 5.3 11.7 280 535 11.6 11,000 2.4 x 9.1 x 2.9 96 x 360 x 114
C800 HP NG, P, LG, DG 800 33 5.3 11.7 280 535 10.9 10,300 2.4 x 9.1 x 2.9 96 x 360 x 114
C1000 LP NG 950 31 6.7 14.7 280 535 11.6 11,000 2.4 x 9.1 x 2.9 96 x 360 x 114
C1000 HP NG, P, LG, DG 1000 33 6.7 14.7 280 535 10.9 10,300 2.4 x 9.1 x 2.9 96 x 360 x 114
LIQUID FUELS (5)
C30 D, A, K 29 25 0.31 0.69 275 530 14.4 13,700 0.76 x 1.5 x 1.9 30 x 60 x 70
C65 D, A, K 65 29 0.49 1.08 309 588 12.4 11,800 0.76 x 1.9 x 1.8 30 x 77 x 76
C65 ICHP D, A, K 65 29 0.49 1.08 309 588 12.4 11,800 0.76 x 2.2 x 2.4 30 x 87 x 93
C200 D 190 30 1.3 2.90 280 535 10.9 10,300 1.7 x 3.8 x 2.5 67 x 150 x 98

(1) Nominal full power performance at ISO conditions: 59° F, 14.696 psia, 60% RH
(2) Height dimensions are to the roofline. Exhaust outlet can extend up to 7 inches above the roofline.
(3) Models available to operate on these different fuels: NG – Natural Gas; P – Propane; LG – Landfill Gas; DG – Digester Gas
(4) Hazardous Location units suitable for use in potentially explosive atmospheres (UL Class I, Division 2 or Atex Class I, Zone 2)
(5) Models available to operate on these different fuels: D – Diesel; A – Aviation; K – Kerosene